install sewage ejector pump
install sewage ejector pump

WYTYW

YW Type Vertical Cast Iron Submersible Sewage Pump

Flow Range:8-400m³/h
Head Range:5-60m
Inlet/Outlet Range:DN25-DN200
Motor Power:0.75-45kw
Submersible Depth:0.5-5m
Send an inquiry
     YW Type Vertical Cast Iron Submersible Sewage Pump
The YW vertical cast iron single-pipe submersible sewage pump launched by WYT is a type of sewage submersible pumps, it combines the durability of cast iron construction with advanced submersible technology, enabling it to effectively pump water containing solids, sludge, and debris—functioning reliably as a heavy-duty sewage septic pump for various onsite waste systems. This cast iron water pump features a vertical, compact design that facilitates easy installation in confined spaces, making it straightforward to install sewage ejector pump models even in tight utility pits; while its submersible operation eliminates the need for above-ground pump houses, reducing both installation costs and footprint. 

Application Scenarios


  • Municipal engineering
Used for the drainage system of urban sewage treatment plants, sewage drainage stations in residential areas, etc., to discharge domestic sewage and industrial wastewater.
  • Industrial wastewater treatment
Suitable for industries such as chemical, petroleum, pharmaceutical, mining, papermaking, cement plants, steel mills, power plants, coal processing, etc., for the treatment of wastewater and waste from conveyor belt particles.
  • Construction site
Used for mud discharge and rainwater collection systems on construction sites to ensure a clean and safe environment.

 

Product Advantage


  • Strong sewage discharge capacity
The vertical cast iron single tube submersible sewage pump has strong sewage discharge capacity and can effectively pass through solid particles and long fibers with larger diameters without blockage.
  • Efficient and energy-saving
The pump body design is reasonable, the matching motor power is small, and the energy-saving effect is significant. Meanwhile, by adopting advanced hydraulic models, the efficiency of the pump has been improved.
  • Automatic control
A fully automatic protection control box can be equipped according to user needs—similar to the setup when you install a sewage ejector pump—to effectively protect the pump from water leakage. This added layer of safety ensures reliable operation, much like a durable sewage septic pump, while also helping to minimize potential sewage ejector pump replacement cost over time.

 
YW Type Vertical Cast Iron Submersible Sewage Pump VS QW Type Submersible Sewage Pump 
Comparative table
Comparison ItemYW Type Vertical Cast Iron Submersible Sewage PumpQW Type Submersible Sewage Pump
Motor PositionMotor is mounted above liquid level, completely out of sewage, no risk of motor water ingress.Pump and motor are fully submerged inside sewage, motor works under water.
Installation MethodTop‑mounted vertical installation, pump body immersed in liquid; submergence depth 0.5‑7m, single‑pipe / double‑pipe optional. Can be fixed on tank cover.Whole unit sinks into sump; support coupling base or mobile installation, requires enough underwater space.
Maintenance OperationMotor above tank, inspection and component replacement without draining tank sewage; only submerged pump head needs checking. Pump & motor are underwater; most maintenance work requires lifting the whole pump out of sewage pit.
Application RestrictionsGood for medium with solid particles & fiber; medium temperature ≤60℃, PH 5‑9. Long shaft design, not fit for excessively deep sump.Wide flow‑head range; suitable for various sewage pits. Subject to submergence depth limit, vulnerable to cable aging in polluted water.
YW Type Vertical Cast Iron Submersible Sewage Pump FAQ 

Q1: What kind of liquid media can the YW Type Vertical Cast Iron Submersible Sewage Pump handle?

A: It can pump sewage with solid particles and long‑fiber waste. Medium temp ≤60℃, density 1‑1.3kg/dm³, PH 5‑9, for factory and municipal sewage. Not for strong corrosive or high‑temperature fluid.

WTY Conclusion: YW is suitable for common particle‑containing sewage within given working conditions.

Q2: Is priming required before starting the YW Type Vertical Cast Iron Submersible Sewage Pump?

A: No priming needed. The pump body submerges in liquid (0.5‑7m depth) for direct start. Prohibit long‑time dry‑running to protect mechanical seal.

WTY Conclusion: No pre‑priming simplifies field startup for YW pump.

Q3: What is the main advantage of YW pump versus WQ submersible sewage pump?

A: YW’s motor sits above liquid, no submersion risk. Maintenance can be done without draining sewage or lifting pump. Limited by submergence depth. WQ needs hoisting for service.

WTY Conclusion: Select YW for easier maintenance and better motor safety.